1. Triggerwise requirement - the Kstop-Charged trigger bit is "ON". We do not care about other bits(components).
2. BLC tracking is succeeded.
3. PDC tracking is succeeded. 1 track on at least PDC L or R. i.e. Possible proton number is up to 2 in an event.
4. Reaction vertex is within the target cell - fiducial volume selection.
5. Stopped kaon selection with Kstop ID function.
6. Proton selection on PB/NT with proton ID function.
Below, DCA-selected spectra are exhibitted. The black-colored spectrum is the one with DCA<5.0 mm, while the red-colored is the one with DCA > 5.0 mm. Note that the proton from
The DCA spectrum for proton events from stop K^- on 4He same is shown below.
DeltaT(T0->PA) = Tpa - Tt0 - TOFkstop - TOFsec.
The gate conditions are:A. DeltaT(T0->PA) < -0.3 - large in-flight contamination is expected (black)
B. | DeltaT(T0->PA) | < 0.3 - events from primary reaction (red)
C. 0.3 < DeltaT(T0->PA) < 0.8 - delayed events from long-lived atomic orbit or possibly Lambda decay (green)
D. 0.8 < DeltaT(T0->PA) - delayed events from long-lived atomic orbit (sky-blue)
.The resulting spectra are overlayed below. When prompt-gate-timing is selected (condition B - red), then the component from two-nucleon phase space looks emphasized.